For the G01L01 fan, Hyundai’s new requirements are: Air volume 5.2±10% m³/min, Noise 47dB(A).We randomly took out five G01L01 fans from the warehouse, change the capacitor of G01L01 fan from 1.0uf to 0.85uF, and there are no other changes, and then airlifted to Hyundai, Hyundai’s test result is that the noise does not meet the requirements.