Machines have a setting called sprue break that allows the injection unit to move back prior to mold open. In some cases adding sprue break will allow the sprue to break cleanly away from the nozzle tip and may resolve a sprue sticking issue. If using sprue break stay very aware of any nozzle drool as it will lead to damage of the tip or sprue bushing over time (and may well cause sticking).