The inner tank roof shall be self-supporting per API STD 620.The inner tank roof-to- shell (compression ring) joint shall be as shown in detail (e), (f), (f-1) or (g) of Figure 5-6 in API STD 620.The minimum anchorage shall also be designed for three times the internal design pressure.