When Feature Sensing is ON, the card will be fed as follows. 1) The drive will quickly feed the card to the programmed strip distance (set on the SET UNITS screen of the HMI touch screen), 2) The drive will then feed slowly until the sensor/amplifier signals that the feature is detected. 3) The drive will stop and trigger the shear to cut the strip. So to find the first registration feature and cut the leading edge scrap, the feature must be no more than 1 strip width from the sensor. See Section 6.3.4.