The tower is now updated with the latest changes in the test-sw. The changes takes care of the voltage measurements of the 1.1V 2,5V and 3.3V internal power supplies. The outputs are loaded with 200mA and the voltage measurement have an error correction including the test-pin resistance. The test limits are the same, but the number of digits are now 5 (it was 2 before). All the boards, except the 1400, have been updated with these changes now.