L3.1 At outer tank shell penetrations and penetrations through the elevated foundation, loads are applied from the internal pipes and the external pipes.Unless project specific external pipe loadings are provided by Air Products, the allowable stresses in the outer tank due to local load from the annular space piping only shall be limited to 50% of the allowable stress values stated in Section L2.5, unless otherwise specified in PES.