For class II tools, capacitors shall not be connected to accessible metal parts, and their casings, if of metal, shall be separated from accessible metal parts by supplementary insulation.This requirement does not apply to capacitors complying with the requirements for protective impedance specified in 9.1 and 21.36.Compliance is checked by inspection and by the tests specified for supplementary insulation.