Kyb-1 smoke sensor is selected. The smoke sensor is installed on the top of the driving drum (downwind). When the environmental smoke concentration exceeds the limit due to the slipping of belt and drum, the sensor will send back the fault signal, the controller will alarm, display the fault and send out the normal shutdown command.